<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-09 13-11-31
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 51 dBuV YLEX
Pilot RDS Phase Difference
7.4 kHz 2.4 kHz 65 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 63 kHz 19020 1,2250
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,0 dBr 3,03 dBr 4,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 2 (Affairs) 0 1 1 1 13:11, 9.12.2025
RT
"YleX Etusivu: Teemu Seppänen "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6203, 6207, 6205, 6201
FM Scope Max at: 63 kHz MIN: 10 kHz % above 76 kHz: 1,2250 Acquired: 2025/12/09 13.10.27 Total samples: 19020 Equivalent time: 0:15:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,7 dBr MIN: 0,0 dBr AVE: 3,03 dBr % above 12,2 dBr: 0,0 Last value: 0,9 dBr (2025/12/09 13.10.27) 12.56 12.58 13.00 13.02 13.04 13.06 13.08 13.10 0 2 4 Pm [dBr]